Single skin sheets come in a range of colours. Below is the specification.

R.C. 32/1000

Single skin R.C. 32/1000

R.C. 32/1000/R

Single skin R.C. 32/1000R

Curved sheets

Curved sheets are as easy to fix as any other cladding system providing the following simple recommendations are adhered to:

  1. The sheets should be fastened to the supporting framework by a self-drilling type fastener.
  2. Care must be taken to apply the fixings correctly to ensure a good weathertight seal at the point where the sheet is fixed.
  3. Sheeting should commence at a fixed point, such as a corner unit and then proceed away from that point.
  4. It is always imperative to commence sheeting in correct alignment to the supporting structure. (This is vital as only a minimum adjustment or realignment with the sheeting is possible as the work proceeds).
  5. Each tier of sheeting should be laid complete and fixed before the next is started.
Dimensional Limits
Dimension Min Max
DIM 'A' 150*mm 2000mm
DIM 'B' 150*mm 2000mm
R1 400mm 1535mm
X 135°
PANEL LENGTH 5000mm

DIM 'B' is run out leg and will therefore vary.
*Leg 'A' or 'B' must be a minimum of 400mm for manufacturing purposes.

Diagram of the dimensional limits of curved sheets

Vented Sheets

This provides an effective way of ventilating walls. Ventclad is available in 32mm deep profile and in any length up to a maximum of 6 metres. Either whole or part of the sheet may be vented.

R.C. 32/1000/R

Vented sheet

Technical information

Vents are 50mm centres but can be variable if a higher degree of ventilation is required.

Due to the manufacturing process a minimum border of 50mm at the top and 300mm at the bottom of each sheet will be unvented.

The maximum sheet length available is 6 metres.

Laid weight
0.5mm - 4.81 kg per m²
0.65mm- 6.26 kg per m²